MOQ : 10 Units

Fire Safety Door Specification

  • Control Type
  • Manual
  • Installation Type
  • Wall Mounted, Hinged
  • Features
  • Heat Resistant, Smoke Proof, Durable Hinges, Panic Bar, Secure Latch Mechanism
  • Mounting Type
  • Wall Mount
  • Coating Type
  • Powder Coated Finish
  • Fire Class
  • Class A, B & C
  • Working Temperature
  • Up to 1200C
  • Shape
  • Rectangular
  • Coverage Area
  • Area at the Installed Entry or Exit Point
  • Technology
  • Insulated Steel Core with Special Fireproof Filling
  • Application
  • Fire Protection for Commercial and Industrial Buildings
 

Fire Safety Door Trade Information

  • Minimum Order Quantity
  • 10 Units
  • FOB Port
  • Ahmedabad
  • Payment Terms
  • Cash on Delivery (COD), Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 2 Week
  • Sample Available
  • Yes
  • Main Domestic Market
  • All India
 

About Fire Safety Door

There is a Fire Safety Door offered by us that is a sealed door between compartments or areas. They act as a barrier to the spread of fire, heat and smoke, limiting its effect whilst allowing enough time for occupants to evacuate to a place of safety. At a glance, fire safety doors dont look too different from the other internal doors in a building. The fire safety door is a crucial safety feature of any building in which people live, work or visit.

Product Details

Door Type

Fireproof

Material

Stainless Steel

Finish

Powder Coated



Built for Maximum Fire Safety

Engineered to withstand temperatures up to 1200C, the door utilizes a galvanized steel structure and insulated fireproof core. Its robust pressed steel frame, fitted with an intumescent seal, expands in high heat to prevent smoke and flames from penetrating, ensuring effective compartmentalization.


Flexible Installation and Functionality

With options for single or double leaf designs and both right or left-handed openings, this door adapts to different entry requirements. The installation process is streamlined, as the door is wall-mounted and hinged, ensuring secure and easy placement at any commercial or industrial exit or entry point.


Advanced Security and User Safety

Heavy-duty locksets, durable hinges, panic hardware, and a secure latch mechanism combine to provide superior security. Optional fire-rated glass panels allow for visibility and light while maintaining high safety standards. The powder-coated red finish enhances both aesthetic and corrosion resistance.

FAQs of Fire Safety Door:


Q: How does the Fire Safety Door provide protection during a fire?

A: The door uses an insulated steel core with a special fireproof filling, robust galvanized steel sheets, and an intumescent seal. In the event of a fire, the seal expands to block smoke and flames, ensuring up to 120 minutes of fire resistance, and helping to safeguard occupants and property.

Q: What types of buildings are suitable for installing this fire safety door?

A: This fire safety door is designed for commercial and industrial buildings, including offices, warehouses, factories, hotels, and hospitals, where enhanced fire protection and compartmentalization are crucial.

Q: When should I consider choosing a single or double leaf door configuration?

A: Single leaf doors are ideal for standard entryways, while double leaf doors are recommended for wider access areas, frequently used in high-traffic locations or as main exits, providing flexibility based on the buildings needs.

Q: Where is the best place to install the Fire Safety Door?

A: Install this door at entry and exit points, corridors, staircases, or compartmental boundaries within your building to effectively contain fire and smoke within critical zones, ensuring safer evacuation routes and compliance with fire safety regulations.

Q: What is the process for installing and maintaining this fire safety door?

A: Installation is straightforward: the door is wall-mounted using durable hinges onto the steel frame. Routine maintenance involves periodic inspections for lock, panic bar, hinge integrity, and verifying the effectiveness of the intumescent seal for optimal performance.

Q: What are the benefits of having an optional glass vision panel with fire-rated glass?

A: The fire-rated glass vision panel allows visibility without compromising safety, supporting evacuation efforts and general monitoring. It maintains the doors integrity for up to the rated fire resistance duration while preventing the passage of flames and smoke.

Q: Can this fire safety door help with sound insulation as well?

A: Yes, sound insulation is available as an additional feature, helping to minimize noise transmission between compartments, making it suitable for environments where both fire safety and acoustic control are required.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



We deal only in bulk quantity orders.